一区二区模特视频|免费 亚 在线 婷|日本福利免费导航|婷婷中文日逼视频|卢森堡玖玖资源Av|中日无码高清视频|亚洲国产原创第一|成人综合福利导航|午夜不卡免费AV|欧美黄色一级精品

歡迎光臨瑞昌明盛進(jìn)出口貿(mào)易有限公司官網(wǎng)!
主營業(yè)務(wù)|產(chǎn)品PLC系統(tǒng) DCS系統(tǒng) 伺服系統(tǒng) 機(jī)器人系統(tǒng)(模塊 備件)
全國咨詢熱線:+86 15270269218
聯(lián)系我們
瑞昌明盛進(jìn)出口貿(mào)易有限公司
手機(jī):+86 15270269218
QQ:3136378118
郵箱:stodcdcs@gmail.com
地址 :江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)
聯(lián)系人:麥女士
您的位置: 首頁>>產(chǎn)品展示 >
產(chǎn)品展示 》 ABB 》 TRICONEX 3301模塊備件說明書

TRICONEX 3301模塊備件說明書

型號(hào):TRICONEX 3301

聯(lián)系人:肖經(jīng)理
公司名稱:瑞昌明盛進(jìn)出口貿(mào)易有限公司
公司地址:廈門市思明區(qū)呂嶺路1733號(hào)創(chuàng)想中心2009-2010單元
手機(jī):+86 15270269218
QQ:3136378118
郵箱:stodcdcs@gmail.com

假設(shè)您設(shè)置了一個(gè)系統(tǒng),該系統(tǒng)包含10個(gè)獨(dú)立的I/O模塊
遙控網(wǎng)絡(luò)機(jī)箱。如果使用直接連接將數(shù)據(jù)傳輸?shù)?br />每個(gè)I/O模塊都需要11個(gè)連接才能傳輸所有數(shù)據(jù)
數(shù)據(jù)(一個(gè)連接到通信模塊,一個(gè)連接
至十個(gè)I/O模塊中的每一個(gè))。如果使用機(jī)架優(yōu)化連接
傳輸數(shù)據(jù)時(shí),您只需要一個(gè)連接——連接
連接到通訊模塊。由于1756-CNB模塊僅限于64個(gè)
連接,使用機(jī)架優(yōu)化連接可以節(jié)省寶貴的資源。
重要提示:盡管機(jī)架優(yōu)化連接提供了一種
使用資源,它們的使用有一些限制:
•您只能使用機(jī)架優(yōu)化連接發(fā)送數(shù)據(jù)
進(jìn)出離散數(shù)字I/O模塊。模擬輸入/輸出
需要直接連接。
•機(jī)架優(yōu)化連接可以包含I/O數(shù)據(jù)和狀態(tài)
僅供參考。其他模塊信息,例如
診斷,不可通過機(jī)架優(yōu)化
聯(lián)系
•您必須對(duì)單個(gè)數(shù)據(jù)庫中的所有數(shù)據(jù)使用一致的RPI
機(jī)架優(yōu)化連接。因?yàn)槟阌玫氖且粋€(gè)
連接發(fā)送數(shù)據(jù)時(shí),所有數(shù)據(jù)都將
以統(tǒng)一速率在同一消息中傳輸。
混合通信格式
當(dāng)同一機(jī)箱中存在多個(gè)I/O模塊時(shí),用戶可以混合使用
不同I/O模塊的通信格式。I/O模塊設(shè)置為使用
機(jī)架優(yōu)化將以配置的RPI速率進(jìn)行通信
1756-CNB模塊。為直接通信配置的I/O模塊
將以設(shè)定的RPI進(jìn)行通信,而忽略CNB RPI。
重要提示:在RSLogix5000中設(shè)置正確的I/O配置后,
ControlNet上的I/O通信直到
RSNetWorx for ControlNet軟件已運(yùn)行。使用RSNetWorx
設(shè)置ControlNet網(wǎng)絡(luò)的網(wǎng)絡(luò)參數(shù)。TRICONEX 3301模塊備件說明書 TRICONEX 3301模塊備件說明書 TRICONEX 3301模塊備件說明書 Assume you have set up a system that contains 10 discrete I/O modules in a remote ControlNet chassis. If you used direct connections to transfer data to each of the these I/O modules, you would need 11 connections to transfer all of the data (one connection to the communication module and 1 connection to each of the ten I/O modules). If you used a rack-optimized connection to transfer the data, you would only need a single connection – the connection to the communication module. Since the 1756-CNB module is limited to 64 connections, using rack-optimized connections can save valuable resources. Important:Although rack optimized connections offer an efficient way to use resources, there are a few limitations on their use: • You can only use rack optimized connections to send data to and from discrete digital I/O modules. Analog I/O requires direct connections. • Rack optimized connections can contain I/O data and status information only. Additional module information, such as diagnostics, is not available through a rack-optimized connection. • You must use a consistent RPI for all data in a single rack-optimized connection. Since you are using a single connection to send the data, all of the data will be transferred in the same message at a uniform rate. Mixing Communication Formats When multiple I/O modules exist in the same chassis, the user can mix Comm Formats for the different I/O modules. I/O modules set up to use Rack Optimization will communicate at the rate of the RPI configured for the 1756-CNB module. I/O modules configured for direct communication will communicate at their set RPI and ignore the CNB RPI. Important:After the proper I/O configuration is set up in RSLogix5000, I/O communication on ControlNet is not established until RSNetWorx for ControlNet software is run. RSNetWorx is used to set up the network parameters of a ControlNet network.
在線客服
聯(lián)系方式

熱線電話

+86 15270269218

上班時(shí)間

周一到周五

公司電話

+86 15270269218

二維碼