比方USB接口映射的COM,正在PPI選項卡,*緊張的參數(shù)是傳輸?shù)牟ㄌ芈蕟卧荎bps,也就是每秒傳送的二能夠選.Kbps,.Kbps大概.Kbps,有的編程電纜不撐持.Kbps的波特率。注釋一下常常間這個觀點,它指與通信的*長工夫值s,這個站天為零指的是編程用的計較機(jī)正在中的站天。*占天是STEP-Micro/win休止中的其他主站的天,能夠的。接下來進(jìn)入體系塊設(shè)置plc的通信端口參數(shù)的要領(lǐng)。SIEMENS/西門子軟件6ES7811-0CC06-0YA5安裝辦法憑據(jù)西門子8月1日公布的2019財年(2018年10月1日-2019年9月30日)三季度財報,因為化和活動的需求下落,其三季度產(chǎn)業(yè)利潤降落12%。

When Siemens PLC is programmed with step software, it is time to configure communication and download user's method. In order to realize the communication between PLC and computer, as usual, pc/ppi multi fan cable or usb/ppi multi master station cable, pc/ppi multi master station programming cable are used for the communication between PLC and RS port. At present, almost all notebook computers have no RS port, and less and less desktop contesting machines have RS port, so few programming cables are used, and more and more usb/ppi multi station programming communication cables are used to realize the conversion of usb-rs port, There are many domestic USB cables compatible with Siemens products in the market. They are actually a combination of usb-rs converter and pc/ppi adapter. Siemens/ Siemens software 6es7811-0cc06-0ya5 installation essentials. They map the USB port to an RS port, commonly known as COM port. It is necessary that it cannot be used under the control of windows and is not supported Kbps baud rate per second, gkljbsbdxmz741 use this kind of cable to connect the USB port of the computer and the RS port of my PLC, install the drive step of the USB cable, open the control panel of windows, double-click the system, Hardware tab, stand-alone equipment, port file folder, and you can see the USB port mapped to com. This is how we set the communication port of the computer. Open the communication folder of the command input, double-click the settings in this, pg/pc interface, open the setting pgmunicati is on the PPI option card. * the important parameter is that the baud rate unit transmitted is Kbps, that is, the number of binary bits transmitted per second, which can be selected Kbps,. Kbps probably Kbps, some programming cables are not supported Baud rate of Kbps. Note: this view often refers to the * long time value s of communication. This station day is zero, which refers to the station day when the computer used for programming is in progress* Zhantian is the day of other main stations in step micro / win rest. It can. Next, enter the essentials of setting the communication port parameters of PLC in the system block. Siemens/ Siemens software 6es7811-0cc06-0ya5 installation method
According to Siemens' financial report for the third quarter of fiscal 2019 (October 1, 2018 September 30, 2019) released on August 1, due to the falling demand for chemicals and activities, its industrial profit in the third quarter fell by 12%.







客服1